DESALINATION · PRODUCTS

Reverse osmosis, nanofiltration and special membranes

The complete Clariphex range from the Czech Republic — 21 series and 51 element models in 4" × 40" and 8" × 40" — with the performance figures from each official datasheet. We use these elements in the desalination and treatment units we design and build.

BRANEX · BRACKISH WATER REVERSE OSMOSIS

Seven series for saline wells and industrial water

Brackish water typically holds 2,000–10,000 mg/L of salts, while drinking water should stay below about 500 mg/L. The BRANEX range covers every priority — lowest energy, fouling resistance or the highest rejection.

BRANEX LE — Clariphex · Czech Republic
Low energy · brackish water RO

BRANEX LE

Clariphex · Czech Republic

Optimised support and thin-film composite layers give 99.3 % stable rejection at about 30 % lower pressure than conventional brackish-water membranes — cutting RO energy use by up to a third without losing water quality.

Best for
Saline wells, irrigation and drinking water, solar-powered units
Test conditions
2,000 ppm NaCl · 15.5 bar (225 psi) · 25 °C · pH 8 · 15 % recovery
Max. pressure
41 bar (600 psi)
Max. temperature
45 °C
pH (operation / cleaning)
2–11 / 1–13
Feed limits
SDI₁₅ ≤ 5 · free chlorine < 0.1 ppm
Element sizes
8" × 40": 1016 × 201 mm · 4" × 40": 963 × 99 mm
ModelActive areaPermeate flowMin. rejectionStable rejection
BRANEX-LE-8x40-40037.2 m² · 400 ft²43 m³/d · 11,350 gpd99.10 %99.30 %
BRANEX-LE-8x40-44041 m² · 440 ft²48 m³/d · 12,560 gpd99.10 %99.30 %
BRANEX-LE-4x40-827.6 m² · 82 ft²8.5 m³/d · 2,250 gpd99.00 %99.30 %
BRANEX XLE — Clariphex · Czech Republic
Extra low energy · highest flux

BRANEX XLE

Clariphex · Czech Republic

A modified surface chemistry and larger specific area make XLE one of the highest-flux, lowest-energy elements available, with better hydrophilicity against fouling. Well suited to low-salinity wells and municipal wastewater reuse.

Best for
Low-salinity wells, wastewater reuse
Test conditions
2,000 ppm NaCl · 15.5 bar (225 psi) · 25 °C · pH 8 · 15 % recovery
Max. pressure
41 bar (600 psi)
Max. temperature
45 °C
pH (operation / cleaning)
2–11 / 1–13
Feed limits
SDI₁₅ ≤ 5 · free chlorine < 0.1 ppm
Element sizes
8" × 40": 1016 × 201 mm · 4" × 40": 963 × 99 mm
ModelActive areaPermeate flowMin. rejectionStable rejection
BRANEX-XLE-8x40-40037.2 m² · 400 ft²47.5 m³/d · 12,500 gpd98.00 %99.00 %
BRANEX-XLE-8x40-44041 m² · 440 ft²53 m³/d · 14,000 gpd98.00 %99.00 %
BRANEX-XLE-4x40-827.6 m² · 82 ft²9.1 m³/d · 2,400 gpd98.00 %99.00 %
BRANEX FRLE — Clariphex · Czech Republic
Fouling resistant + low energy

BRANEX FRLE

Clariphex · Czech Republic

Combines fouling resistance with about 30 % lower operating pressure and up to 99.3 % rejection — for feeds prone to biofouling or organic contamination where energy also matters.

Best for
Wells with biological or organic load
Test conditions
2,000 ppm NaCl · 15.5 bar (225 psi) · 25 °C · pH 8 · 15 % recovery
Max. pressure
41 bar (600 psi)
Max. temperature
45 °C
pH (operation / cleaning)
2–11 / 1–13
Feed limits
SDI₁₅ ≤ 5 · free chlorine < 0.1 ppm
Element sizes
8" × 40": 1016 × 201 mm · 4" × 40": 963 × 99 mm
ModelActive areaPermeate flowMin. rejectionStable rejection
BRANEX-FRLE/34-8x40-40037.2 m² · 400 ft²40 m³/d · 10,500 gpd99.10 %99.30 %
BRANEX-FRLE/34-4x40-827.6 m² · 82 ft²7.2 m³/d · 1,900 gpd99.00 %99.30 %
BRANEX FR — Clariphex · Czech Republic
Fouling resistant

BRANEX FR

Clariphex · Czech Republic

Surface modification optimises charge, smoothness and hydrophilicity so organics and microorganisms stick less — lower fouling rates and longer membrane life on difficult industrial feeds.

Best for
Industrial effluents, surface and drainage water
Test conditions
2,000 ppm NaCl · 15.5 bar (225 psi) · 25 °C · pH 8 · 15 % recovery
Max. pressure
41 bar (600 psi)
Max. temperature
45 °C
pH (operation / cleaning)
2–11 / 1–13
Feed limits
SDI₁₅ ≤ 5 · free chlorine < 0.1 ppm
Element sizes
8" × 40": 1016 × 201 mm · 4" × 40": 963 × 99 mm
ModelActive areaPermeate flowMin. rejectionStable rejection
BRANEX-FR-8x40-40037.2 m² · 400 ft²42 m³/d · 11,100 gpd99.35 %99.50 %
BRANEX-FR/34-8x40-40037.2 m² · 400 ft²42 m³/d · 11,100 gpd99.35 %99.50 %
BRANEX-FR-4x40-827.6 m² · 82 ft²7.6 m³/d · 2,000 gpd99.30 %99.50 %
BRANEX XFR — Clariphex · Czech Republic
Extra fouling resistant

BRANEX XFR

Clariphex · Czech Republic

A denser, more hydrophilic selective layer with an ultra-smooth surface gives top resistance to organic and biological fouling, easy cleaning and stable long-term performance.

Best for
Feeds with heavy organic or biological load
Test conditions
2,000 ppm NaCl · 15.5 bar (225 psi) · 25 °C · pH 8 · 15 % recovery
Max. pressure
41 bar (600 psi)
Max. temperature
45 °C
pH (operation / cleaning)
2–11 / 1–13
Feed limits
SDI₁₅ ≤ 5 · free chlorine < 0.1 ppm
Element sizes
8" × 40": 1016 × 201 mm · 4" × 40": 963 × 99 mm
ModelActive areaPermeate flowMin. rejectionStable rejection
BRANEX-XFR-8x40-40037.2 m² · 400 ft²43 m³/d · 11,350 gpd99.40 %99.60 %
BRANEX-XFR/34-8x40-40037.2 m² · 400 ft²43 m³/d · 11,350 gpd99.40 %99.60 %
BRANEX-XFR-4x40-827.6 m² · 82 ft²7.8 m³/d · 2,050 gpd99.40 %99.60 %
BRANEX HR — Clariphex · Czech Republic
High rejection · industrial water

BRANEX HR

Clariphex · Czech Republic

Built for industrial brackish-water treatment at low pressure, with high rejection of salts and of hard-to-remove contaminants such as total organic carbon (TOC) and silica (SiO₂).

Best for
Boiler feed and process water, TOC and silica removal
Test conditions
2,000 ppm NaCl · 15.5 bar (225 psi) · 25 °C · pH 8 · 15 % recovery
Max. pressure
41 bar (600 psi)
Max. temperature
45 °C
pH (operation / cleaning)
2–11 / 1–13
Feed limits
SDI₁₅ ≤ 5 · free chlorine < 0.1 ppm
Element sizes
8" × 40": 1016 × 201 mm · 4" × 40": 963 × 99 mm
ModelActive areaPermeate flowMin. rejectionStable rejection
BRANEX-HR-8x40-40037.2 m² · 400 ft²43 m³/d · 11,350 gpd99.40 %99.70 %
BRANEX-HR-8x40-44041 m² · 440 ft²48 m³/d · 12,560 gpd99.40 %99.70 %
BRANEX-HR-4x40-827.6 m² · 82 ft²8.5 m³/d · 2,250 gpd99.30 %99.50 %
BRANEX HRFR — Clariphex · Czech Republic
High rejection + fouling resistant

BRANEX HRFR

Clariphex · Czech Republic

Delivers a consistent 99.7 % rejection, so a single-stage RO system can meet strict effluent quality in most industrial applications, with predictable flux and a competitive cost.

Best for
Single-pass industrial systems
Test conditions
2,000 ppm NaCl · 15.5 bar (225 psi) · 25 °C · pH 8 · 15 % recovery
Max. pressure
41 bar (600 psi)
Max. temperature
45 °C
pH (operation / cleaning)
2–11 / 1–13
Feed limits
SDI₁₅ ≤ 5 · free chlorine < 0.1 ppm
Element sizes
8" × 40": 1016 × 201 mm · 4" × 40": 963 × 99 mm
ModelActive areaPermeate flowMin. rejectionStable rejection
BRANEX-HRFR/34-8x40-40037.2 m² · 400 ft²43 m³/d · 11,350 gpd99.40 %99.70 %
BRANEX-HRFR-8x40-827.6 m² · 82 ft²8.6 m³/d · 2,250 gpd99.30 %99.70 %
MARIS · SEAWATER REVERSE OSMOSIS

Five series for coastal desalination

Seawater carries more than 35,000 ppm of salts, so only membranes with 99.3 % rejection or more can give potable water in a single pass. MARIS elements are tested at 32,000 ppm and 55 bar.

MARIS HR — Clariphex · Czech Republic
High rejection seawater RO

MARIS HR

Clariphex · Czech Republic

Clariphex’s flagship seawater element: sustained high salt and boron rejection, a thicker, more cross-linked sheet for chemical resistance and shortened leaves that reduce concentration polarisation and local fouling.

Best for
Potable water from seawater and beach wells
Test conditions
32,000 ppm NaCl · 55 bar (800 psi) · 25 °C · pH 8 · 8 % recovery
Max. pressure
83 bar (1,200 psi)
Max. temperature
45 °C
pH (operation / cleaning)
2–11 / 1–13
Feed limits
SDI₁₅ ≤ 5 · free chlorine < 0.1 ppm
Element sizes
8" × 40": 1016 × 201 mm · 4" × 40": 963 × 99 mm
ModelActive areaPermeate flowMin. rejectionStable rejectionBoron rejection
MARIS-HR-8x40-40037.2 m² · 400 ft²24.5 m³/d · 6,500 gpd99.65 %99.80 %—
MARIS-HR-4x40-827.6 m² · 82 ft²5 m³/d · 1,320 gpd99.60 %99.75 %—
MARIS XHR — Clariphex · Czech Republic
Extra high rejection seawater RO

MARIS XHR

Clariphex · Czech Republic

A denser selective layer than MARIS HR gives ultra-high rejection of mono- and divalent ions and strong boron removal for the strictest potable-water standards, with non-oxidative post-treatment for long-term stability.

Best for
Strict drinking-water limits, boron
Test conditions
32,000 ppm NaCl · 55 bar (800 psi) · 25 °C · pH 8 · 8 % recovery
Max. pressure
83 bar (1,200 psi)
Max. temperature
45 °C
pH (operation / cleaning)
2–11 / 1–13
Feed limits
SDI₁₅ ≤ 5 · free chlorine < 0.1 ppm
Element sizes
8" × 40": 1016 × 201 mm
ModelActive areaPermeate flowMin. rejectionStable rejectionBoron rejection
MARIS-XHR-8x40-40037.2 m² · 400 ft²23 m³/d · 6,100 gpd99.70 %99.82 %92.00 %
MARIS-XHR-8x40-44041 m² · 440 ft²25 m³/d · 6,600 gpd99.70 %99.82 %92.00 %
MARIS HRLE — Clariphex · Czech Republic
High rejection + low energy seawater RO

MARIS HRLE

Clariphex · Czech Republic

Optimised chemistry and module design keep rejection high at lower operating pressure — substantial energy savings without giving up water quality or output.

Best for
Seawater plants focused on energy cost
Test conditions
32,000 ppm NaCl · 55 bar (800 psi) · 25 °C · pH 8 · 8 % recovery
Max. pressure
83 bar (1,200 psi)
Max. temperature
45 °C
pH (operation / cleaning)
2–11 / 1–13
Feed limits
SDI₁₅ ≤ 5 · free chlorine < 0.1 ppm
Element sizes
8" × 40": 1016 × 201 mm · 4" × 40": 963 × 99 mm
ModelActive areaPermeate flowMin. rejectionStable rejectionBoron rejection
MARIS-HRLE-8x40-40037.2 m² · 400 ft²28 m³/d · 7,400 gpd99.65 %99.80 %92.00 %
MARIS-HRLE-8x40-44041 m² · 440 ft²30 m³/d · 7,900 gpd99.65 %99.80 %92.00 %
MARIS-HRLE-4x40-827.6 m² · 82 ft²6.1 m³/d · 1,600 gpd99.60 %99.70 %—
MARIS XLE — Clariphex · Czech Republic
Extra low energy seawater RO

MARIS XLE

Clariphex · Czech Republic

Higher flux at lower pressure than conventional seawater membranes, with improved hydrophilicity against fouling — for operators maximising output while minimising energy and running cost.

Best for
High output at low energy
Test conditions
32,000 ppm NaCl · 55 bar (800 psi) · 25 °C · pH 8 · 8 % recovery
Max. pressure
83 bar (1,200 psi)
Max. temperature
45 °C
pH (operation / cleaning)
2–11 / 1–13
Feed limits
SDI₁₅ ≤ 5 · free chlorine < 0.1 ppm
Element sizes
8" × 40": 1016 × 201 mm · 4" × 40": 963 × 99 mm
ModelActive areaPermeate flowMin. rejectionStable rejectionBoron rejection
MARIS-XLE-8x40-40037.2 m² · 400 ft²34 m³/d · 9,000 gpd99.60 %99.80 %92.00 %
MARIS-XLE-8x40-44041 m² · 440 ft²37 m³/d · 9,750 gpd99.60 %99.80 %92.00 %
MARIS-XLE-4x40-827.6 m² · 82 ft²6.3 m³/d · 1,660 gpd99.60 %99.65 %—
MARIS HRFR — Clariphex · Czech Republic
High rejection + fouling resistant seawater RO

MARIS HRFR

Clariphex · Czech Republic

For seawater with high organic content and hardness: a special surface treatment reduces foulant adhesion, improves flux recovery after cleaning and extends the time between cleanings.

Best for
Organic-rich or hard seawater
Test conditions
32,000 ppm NaCl · 55 bar (800 psi) · 25 °C · pH 8 · 8 % recovery
Max. pressure
83 bar (1,200 psi)
Max. temperature
45 °C
pH (operation / cleaning)
2–11 / 1–13
Feed limits
SDI₁₅ ≤ 5 · free chlorine < 0.1 ppm
Element sizes
8" × 40": 1016 × 201 mm
ModelActive areaPermeate flowMin. rejectionStable rejectionBoron rejection
MARIS-HRFR-8x40-40037.2 m² · 400 ft²28 m³/d · 7,400 gpd99.65 %99.80 %92.00 %
NEOFLUX · NANOFILTRATION

Four cut-offs from 90 to 500 Dalton

Nanofiltration separates selected salts or organics at much lower pressure than RO — for softening, drinking water, wastewater, near-zero discharge and food, beverage and chemical processing.

NEOFLUX 90 — Clariphex · Czech Republic
Nanofiltration · 90 Da

NEOFLUX 90

Clariphex · Czech Republic

High flux with strong removal of mono- and divalent salts and of organics such as pesticides, herbicides and THM precursors; reduces hardness, colour and turbidity at very low pressure.

Best for
Municipal water, pesticides and organics, paper and dyeing
Test conditions
2,000 ppm MgSO₄ · 4.8 bar (70 psi) · 25 °C · 15 % recovery
Max. pressure
41 bar (600 psi)
Max. temperature
45 °C
pH (operation / cleaning)
3–10 / 2–12
Element sizes
8" × 40": 1016 × 201 mm · 4" × 40": 963 × 99 mm
ModelActive areaPermeate flowStable rejectionMWCO
NEOFLUX-90-40037 m² · 400 ft²31 m³/d · 8,200 gpd≥ 99 %90 Da
NEOFLUX-90-827.6 m² · 82 ft²6 m³/d · 1,580 gpd≥ 99 %90 Da
NEOFLUX 150 — Clariphex · Czech Republic
Nanofiltration · 150 Da

NEOFLUX 150

Clariphex · Czech Republic

A cut-off that fills the gap between existing NF membranes, for precise separation: TOC and THM-precursor removal, monovalent salt separation, decolourisation and concentration of small organics, with good fouling resistance.

Best for
Fine separation, decolourisation
Test conditions
2,000 ppm MgSO₄ · 4.8 bar (70 psi) · 25 °C · 15 % recovery
Max. pressure
41 bar (600 psi)
Max. temperature
45 °C
pH (operation / cleaning)
3–10 / 2–12
Element sizes
8" × 40": 1016 × 201 mm · 4" × 40": 963 × 99 mm
ModelActive areaPermeate flowStable rejectionMWCO
NEOFLUX-150-40037 m² · 400 ft²34 m³/d · 8,950 gpd≥ 98 %150 Da
NEOFLUX-150-827.6 m² · 82 ft²7 m³/d · 1,850 gpd≥ 98 %150 Da
NEOFLUX 280 — Clariphex · Czech Republic
Nanofiltration · 280 Da

NEOFLUX 280

Clariphex · Czech Republic

Ultra-high flux at very low pressure with effective TOC and THM-precursor removal and selective passage of salts — for softening, organic removal from surface and groundwater, and purification processes.

Best for
Softening, surface and groundwater
Test conditions
2,000 ppm MgSO₄ · 4.8 bar (70 psi) · 25 °C · 15 % recovery
Max. pressure
41 bar (600 psi)
Max. temperature
45 °C
pH (operation / cleaning)
3–10 / 2–12
Element sizes
8" × 40": 1016 × 201 mm · 4" × 40": 963 × 99 mm
ModelActive areaPermeate flowStable rejectionMWCO
NEOFLUX-280-40037 m² · 400 ft²47 m³/d · 12,410 gpd≥ 97 %280 Da
NEOFLUX-280-827.6 m² · 82 ft²9.2 m³/d · 2,430 gpd≥ 97 %280 Da
NEOFLUX 500 — Clariphex · Czech Republic
Nanofiltration · 500 Da

NEOFLUX 500

Clariphex · Czech Republic

Extremely high flux with strong retention of divalent salts, free passage of monovalent salts and excellent decolourisation; retains organics of 300–500 Da. Suited to wastewater reuse and municipal treatment.

Best for
Wastewater reuse, colour removal
Test conditions
2,000 ppm MgSO₄ · 4.8 bar (70 psi) · 25 °C · 15 % recovery
Max. pressure
41 bar (600 psi)
Max. temperature
45 °C
pH (operation / cleaning)
3–10 / 2–12
Element sizes
8" × 40": 1016 × 201 mm · 4" × 40": 963 × 99 mm
ModelActive areaPermeate flowStable rejectionMWCO
NEOFLUX-500-40037 m² · 400 ft²50 m³/d · 13,200 gpd≥ 90 %500 Da
NEOFLUX-500-827.6 m² · 82 ft²11 m³/d · 2,900 gpd≥ 90 %500 Da
FORTEX & CHEMX · SPECIAL MEMBRANES

Wastewater, zero liquid discharge, acids and heat

Specialty elements with smooth, dense, chemical- and temperature-resistant layers, made for demanding industrial streams and available customised to the feed.

FORTEX HCO — Clariphex · Czech Republic
High-COD wastewater RO

FORTEX HCO

Clariphex · Czech Republic

Built on Clariphex’s fouling-resistant technology with a tougher sheet for highly polluted, high-COD water: more flux at lower pressure, pH 1–13 cleaning tolerance, a 34-mil spacer and short leaves for better cleaning and flow distribution.

Best for
Industrial effluents with high COD
Test conditions
2,000 ppm NaCl · 15.5 bar (225 psi) · 25 °C · pH 8 · 15 % recovery
Max. pressure
41 bar (600 psi)
Max. temperature
45 °C
pH (operation / cleaning)
3–10 / 2–12
Feed limits
SDI₁₅ ≤ 5 · free chlorine < 0.1 ppm
Element sizes
8" × 40": 1016 × 201 mm
ModelActive areaPermeate flowMin. rejectionStable rejection
FORTEX-HCO-R5037 m² · 400 ft²42 m³/d · 11,000 gpd99.20 %99.60 %
FORTEX-HCO-R10037 m² · 400 ft²44 m³/d · 11,500 gpd99.40 %99.70 %
FORTEX ZLD-XR — Clariphex · Czech Republic
High-ratio brine concentration

FORTEX ZLD-XR

Clariphex · Czech Republic

For zero liquid discharge and brine concentration: high flux even on concentrated brine, a fouling-resistant sheet and wide cleaning tolerance. Five grades concentrate brine to 60,000–130,000 ppm.

Best for
ZLD and brine minimisation
Test conditions
32,000 ppm NaCl · 41 bar (600 psi) · 25 °C · pH 8 · 15 % recovery
Max. pressure
83 bar (1,200 psi)
Max. temperature
45 °C
pH (operation / cleaning)
3–10 / 2–12
Element sizes
8" × 40": 1016 × 201 mm
ModelActive areaPermeate flowMin. rejectionStable rejectionConcentrate TDS
FORTEX-ZLD-XR-6037 m² · 400 ft²———60,000 ppm
FORTEX-ZLD-XR-7037 m² · 400 ft²35.5 m³/d · 8,800 gpd99.60 %99.75 %70,000 ppm
FORTEX-ZLD-XR-8037 m² · 400 ft²34.2 m³/d · 9,050 gpd99.20 %99.50 %80,000 ppm
FORTEX-ZLD-XR-10037 m² · 400 ft²———100,000 ppm
FORTEX-ZLD-XR-12037 m² · 400 ft²———130,000 ppm
FORTEX ZLD-HC — Clariphex · Czech Republic
High-efficiency concentration & separation

FORTEX ZLD-HC

Clariphex · Czech Republic

Performs high-concentration and high-salt separation at sub-high pressure instead of ultra-high pressure, cutting energy use. Brine can be concentrated up to 290,000 ppm; elements withstand 83 bar and can be customised to the stream.

Best for
Resource recovery, intensive ZLD
Test conditions
Na₂SO₄ solution (HC-1/2/3) or NaCl (HC-4) · 25 °C · pH 8
Max. pressure
83 bar (1,200 psi)
Max. temperature
45 °C
pH (operation / cleaning)
3–10 / 2–12
Element sizes
8" × 40": 1016 × 201 mm
ModelActive areaPermeate flowStable rejectionConcentrate TDS
FORTEX-ZLD-HC-137 m² · 400 ft²48 m³/d · 12,650 gpd≥ 90 %290,000 ppm
FORTEX-ZLD-HC-237 m² · 400 ft²35.2 m³/d · 9,300 gpd≥ 97 %250,000 ppm
FORTEX-ZLD-HC-337 m² · 400 ft²32 m³/d · 8,450 gpd≥ 98 %—
FORTEX-ZLD-HC-437 m² · 400 ft²30.2 m³/d · 7,980 gpd≥ 95 %105,000 ppm
CHEMX AR — Clariphex · Czech Republic
Acid-resistant

CHEMX AR

Clariphex · Czech Republic

Acid-resistant elements for purifying acidic solvents, removing metal cations, recovering acid from leach liquors, decolourising mineral acids and recovering metals and electrolytes — for mining, metallurgy and chemicals.

Best for
Mining, metallurgy, chemical processing
Test conditions
2,000 ppm MgSO₄ · 6.8 bar (100 psi)
Element sizes
8" × 40": 1016 × 201 mm · 4" × 40": 963 × 99 mm
ModelActive areaPermeate flowStable rejection
CHEMX-AR-40037 m² · 400 ft²28.7 m³/d · 7,690 gpd98.00 %
CHEMX-AR-827.6 m² · 82 ft²5.6 m³/d · 1,500 gpd98.00 %
CHEMX HT — Clariphex · Czech Republic
High temperature

CHEMX HT

Clariphex · Czech Republic

For systems sanitised with heat instead of chemicals: up to 90 °C in short disinfection cycles and up to 60 °C in continuous service, with steady divalent-salt rejection — for pharmaceutical and food plants.

Best for
Pharmaceutical and food industries
Max. temperature
60 °C continuous · 90 °C for sanitisation
Element sizes
8" × 40": 1016 × 201 mm · 4" × 40": 963 × 99 mm
ModelActive areaPermeate flowStable rejection
CHEMX-HT-40037 m² · 400 ft²30 m³/d · 7,920 gpd≥ 97 %
CHEMX-HT-827.6 m² · 82 ft²5.8 m³/d · 1,530 gpd≥ 97 %

Which membrane fits your water?

Feed water / dutyRecommended series
Saline well for irrigation or drinking water — lowest energyBRANEX LE · BRANEX XLE
Brackish well that tends to foul (organics, bacteria)BRANEX FRLE · BRANEX FR · BRANEX XFR
Industrial water needing the best permeate, incl. TOC and silicaBRANEX HR · BRANEX HRFR
Seawater or beach well — potable water, boron controlMARIS HR · MARIS XHR
Seawater with lower energy or high organic loadMARIS HRLE · MARIS XLE · MARIS HRFR
Softening, sulphate, colour and organics removalNEOFLUX 90 / 150 / 280 / 500
High-COD effluentFORTEX HCO
Brine concentration and zero liquid dischargeFORTEX ZLD-XR · FORTEX ZLD-HC
Acid recovery and metal separation · hot sanitisable systemsCHEMX AR · CHEMX HT

Datasheets open from clariphex.com. Permeate flow of an individual element may vary ±15 % from the stated value and the active area is guaranteed to ±4 %. Stabilised rejection is generally reached after 24–48 hours of operation. Our engineers run a projection on your own water analysis before recommending an element.

Supplying projects in Egypt and across Africa

We export this range from Egypt to projects throughout Africa — Sudan, Libya, Chad, Kenya, Ethiopia, Senegal, Côte d’Ivoire, Nigeria and beyond — with selection support, export documents and after-sales service.

Export to Africa

Have a water analysis?

Send us the analysis of your well or source and the daily volume you need. We will select the membranes and size the complete unit — pre-treatment, high-pressure pump, energy recovery and controls — and send a quotation.